1.003 MW Ground Mount Solar Project in Abu Dhabi

Project Reference

1.003 MW Ground Mount Solar Project in Abu Dhabi

A fixed-tilt PV reference showing how one Abu Dhabi project coordinated array layout, structural geometry and a concrete-foundation support concept.

Installed PV array at the Abu Dhabi project
1,003.2 kWDC capacity
1,824 × 550 WPV modules
57 × 32Tables × modules per table
10°Fixed tilt
Project Configuration

Design Inputs Used for This Reference

The values below describe this project only. They are presented as project inputs rather than universal ratings for a mounting system.

Project capacity1,003.2 kW DC
PV modules1,824 modules rated at 550 W each
Table arrangement57 structural tables, 32 modules per table
Layout alternatives4 × 8 landscape or 2 × 16 portrait
Fixed tilt10°
Project wind input160 km/h
Module dimensions2279 × 1134 × 35 mm
Ground clearance300 mm
Primary aluminum membersAL6005-T5
Foundation conceptConcrete foundations with embedded anchors
Scope note: Final member sizes, connection details and foundation dimensions should follow the approved project drawings and site-specific engineering.
Site View

Repeated Table Geometry Across the Array

Using one 32-module structural unit across the site provides a consistent basis for layout coordination, installation sequencing and component planning.

Repeated PV table rows across the project site

Project view showing the repeated table pattern and overall array scale.

Layout Alternatives

Landscape and Portrait Table Options

The project package evaluates two ways to arrange the same 32-module table count: a 4 × 8 landscape layout and a 2 × 16 portrait layout.

4 × 8 · Landscape

Landscape table

The landscape option places four module rows across eight columns while keeping the project tilt and foundation concept unchanged.

4 by 8 landscape module table drawing
2 × 16 · Portrait

Portrait table

The portrait option uses two module rows across sixteen columns, changing the table geometry and rail arrangement while retaining the same module count.

2 by 16 portrait module table drawing
Structural Concept

Load Path to the Concrete Foundation

The project information shows a conventional fixed-tilt load path from the PV module through the mounting members and into the concrete support.

PV Module→ Module Clamp→ Rail→ Beam→ Pillar & Base→ Embedded Anchor→ Concrete Foundation

Wind value is project-specific

The 160 km/h figure is an input for this reference, not a general rating that should be copied to another site.

Foundation sizing remains site-dependent

The concrete concept defines the support family; final foundation geometry should follow structural reactions and site conditions.

Orientation changes the structure

Landscape and portrait layouts can keep the same module count while changing rail positions, member spans and connection geometry.

Concrete foundation and structural connection detail

Close-up of the support and connection area used in the project reference.

Review a Similar Ground-Mount Project

For a project-specific review, provide the module datasheet, site layout, design wind and snow inputs, tilt requirement, foundation preference and available drawings.

Scroll to Top