Thailand 84.36 kW L-Foot Solar Roof Project

Project Case Study

Thailand 84.36 kW L-Foot Roof Mounting Case Study

This rooftop PV project uses 228 landscape modules, aluminum rails and mechanically fixed roof attachments. The layout is divided into shorter module groups so the array can follow the available roof zones and maintain clearance around roof obstacles.

228-module rooftop PV layout in Thailand
84.36 kW · 228 modules Documented project capacity and module count
Project Record

Key documented values

The figures below are taken from the project information shown on this case page. They describe this installation only and are not universal design values for other roofs.

84.36 kWTotal PV capacity
228PV modules
370 WModule rating
LandscapeModule orientation
1750 × 1038 × 35 mmDocumented module size
29 m/sWind-speed input in the project documents
AL6005-T5Rail material shown
Mechanical fixingRoof attachment approach
Data note: ambiguous “0° landscape mounting angle” and “0 cm vertical snow input” labels from the previous version have been removed from the headline metrics because they can be misread without the original engineering basis.
Roof Layout

Shorter array groups follow the available roof zones

The documented layout uses several table lengths instead of one continuous module row. This allows the PV field to fit around roof edges, penetrations and changes in usable roof area.

Roof plan showing shorter PV tables around roof obstacles

Project roof overview with different row lengths and clear areas around obstacles.

Documented module groups

1 × 15 sets
1 × 26 sets
1 × 324 sets
1 × 423 sets
1 × 51 set
1 × 76 sets
Cross-check: these groups add up to 228 modules, matching the documented module count.
Roof Attachment

Mechanical roof fittings connect the rail system to the building

The mounting schedule identifies L-foot roof fittings used with horizontal aluminum rails. The project is therefore presented as a mechanically fixed system rather than a seam-only clamp installation.

Mechanically fixed L-foot attachment on a metal roof

Close view of the roof fitting and its connection to the metal roof.

What the project record shows

  • Attachment: mechanically fixed roof fitting / L-foot
  • Rails: AL6005-T5 aluminum
  • Module restraint: end clamps and inner clamps
  • Hardware: aluminum and SUS304 where documented
  • Layout logic: attachment positions coordinated with the roof support layout
  • Project limitation: fixing and sealing details must be checked for the actual roof and structure on any new job
Rail Planning

Rail lengths vary with the module group

The project drawing assigns different rail lengths to the 1 × 1 through 1 × 7 groups. That keeps each table matched to its roof zone instead of treating one rail length as a universal value.

Rail lengths shown in the project drawing

Module groupRail length shown
1 × 11300 mm
1 × 22300 mm
1 × 33400 mm
1 × 44400 mm
1 × 55500 mm
1 × 77600 mm (4500 + 3100)

These dimensions are project records, not standard cut lengths for other roofs.

Aluminum rail and module clamp detail

Installed rail and module-clamp detail from the project.

Installation Detail

Roof connection details need project-specific verification

Completed roof attachment and sealing detail

Completed attachment detail showing fastener placement and the finished roof interface.

For a new roof, confirm the actual design inputs

A new mounting layout should be checked against the roof profile, supporting structure, fastener specification, module geometry, local wind and snow requirements, and the required sealing method.

Important: the documented 29 m/s value belongs to this project record. It should not be copied into another project without a site-specific design basis.
What the Case Shows

Three practical takeaways from the layout

1

Roof geometry drives table size

Using several module-group lengths helps fit the array into fragmented roof areas without forcing one long table through every zone.

2

Attachment points are part of the load path

The rails transfer module loads through the roof fittings into the building, so the attachment layout and supporting structure must be coordinated.

3

The BOM follows the approved layout

Rail lengths, roof fittings and clamp quantities change with the table arrangement. A project drawing is more useful than estimating components from system capacity alone.

Project Data

Reference values and scope

  • LocationThailand
  • Capacity84.36 kW
  • Modules228 × 370 W
  • Module size1750 × 1038 × 35 mm
  • OrientationLandscape
  • Array groups1 × 1, 1 × 2, 1 × 3, 1 × 4, 1 × 5 and 1 × 7
  • Roof interfaceMechanically fixed L-foot type fitting
  • Rail materialAL6005-T5
  • Wind input29 m/s in the supplied project information

What this page does not claim

This case study does not present a universal fastener spacing, allowable load, waterproofing guarantee, roof compatibility statement, or reusable engineering approval.

Those items depend on the selected attachment, the actual roof and supporting structure, the module layout, and the design requirements for the new site.